Add to Cart
ABS Box Type 1×8 Sc/Upc G657A1 3.0mm Fiber Optic PLC Splitter
Box Type Splitter Description
Planar waveguide light optical distributor (PLC Splitter), is a kind of planar waveguide integrated optical device, it can be 1260nm ~ 1650nm such a wide range of wavelengths of light power reservation in realization, the distribution of wavelength range covers EPON technology used1310nm, 1490nm and 1550nm three wavelengths. Especially suitable for EPON Ethernet passive optical network access technology FTTP fiber network system, broadband passive optical distributor (POS) use
Box Type Splitter Feature
1. Low Insertion loss and Low PDL
2. Uniform power splitting
3. High reliability
4. Excellent environmental stability
5. Compact size and various package
Box Type Splitter Application
1. FTTx Systems
2. Digital, hybrid and AM-Video systems
3. LAN,WAN and Metro Networks
4. CATV systems
5. Other applications in fiber optic systems
Box Type Splitter Specification
Model | Output tube diameter | Inlet/ outlet fiber length | Pipe Sizes |
1×2 splitter | 0.25mm/0.9mm | 1M | 4mm*7mm*50mm |
1×4 splitter | 0.25mm/0.9mm | 1M | 4mm*7mm*50mm |
1×8 splitter | 0.25mm/0.9mm | 1M | 4mm*7mm*60mm |
1×16 splitter | 0.25mm/0.9mm | 1M | 4mm*12mm*60mm |
1×32 splitter | 0.25mm/0.9mm | 1M | 6mm*20mm*80mm |
1×64 splitter | 0.25mm/0.9mm | 1M | 6mm*40mm*100mm |
1×N Box Type PLC Splitter (Measured at room temperature and excludes connector loss)
Type | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength(nm) | 1260-1650 | ||||||
Insertion loss(dB) | Max | 3.8 | 7.2 | 10.2 | 13.5 | 16.5 | 20.5 |
Loss uniformity(dB) | Max | 0.5 | 0.6 | 0.8 | 1.0 | 1.5 | 2.0 |
Return Loss(dB) | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | |
Polarization Dependent Loss(dB) | Max | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 |
Directivity(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |
Fiber Type | Corning fiber or customer designation | ||||||
Wavelength Dependent Loss(dB) | Max | 0.6 | 0.6 | 0.6 | 0.8 | 0.8 | 0.8 |
Temperature correlation loss-40~85℃(dB) | Typical value | 0.2 | 0.2 | 0.3 | 0.4 | 0.4 | 0.4 |
Max | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
Working Temperature(℃) | -40~85℃ | ||||||
Storage Temperature(℃) | -40~85℃ |
2×N PLC Splitter (Measured at room temperature and excludes connector loss)
type | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | |
Operating Wavelength(nm) | 1260-1650 | ||||||
Insertion loss(dB) | Max | 4.0 | 7.4 | 10.5 | 13.9 | 17.0 | 20.5 |
Loss uniformity(dB) | Max | 0.5 | 0.6 | 0.8 | 1.0 | 1.5 | 2.0 |
Return Loss(dB) | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | |
Polarization Dependent Loss(dB) | Max | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 |
Directivity(dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |
Fiber Type | Corning fiber or customer designation | ||||||
Wavelength Dependent Loss(dB) | Max | 0.6 | 0.6 | 0.6 | 0.8 | 0.8 | 0.8 |
Temperature correlation loss-40~85℃(dB) | Typical value | 0.2 | 0.2 | 0.3 | 0.4 | 0.4 | 0.4 |
Max | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
Working Temperature(℃) | -40~85℃ | ||||||
Storage Temperature(℃) | -40~85℃ |